Product name : Automatic Atomic
Absorption Photometer
|
||||||||||||||||||||||||||||||||||||
Item : ME-AA1800
Series
|
||||||||||||||||||||||||||||||||||||
Details :
|
||||||||||||||||||||||||||||||||||||
Introduce
ME-AA1800 series Atomic Absorption Photometer is
an expert in the use of the latest international technology and
domestic famous universities jointly complete R & D, R & D and application experience with decades of spectroscopic instrument. It include the flame and graphite furnace and hydride generation system, which can be equipped with various accessories,
flexible
configuration program can meet different levels of customer demand. It
can be used for analysis of complex samples
full automatic multi functional.
Specifications
Advance
1. Various analysis
methods can automatically switch, unmanned automatic analysis.
2. Soft, hardware were designed innovation to
ensure the accuracy, safety, ease of use in the analysis of
samples,
equipment maintenance,simple and convenient.
3. Widely used
in hospitals, pharmaceutical, steel, health and
epidemic prevention, metal
smelting industry, geology and mining geology, chemical,water
quality monitoring, food and drink milk, environmental
monitoring, quality inspection, drug, agriculture, toys,
electronics, disease
control, metallurgy, chemical industry, and forestry, etc.
4. Main Features
of model ME-AA1800C & ME-AA1800H:
ME-AA1800C Features
Flame atomizer:
1. Characteristic
concentration (Cu)
: 0.015μg/mL/1%.
2. Detection
limits(Cu):0.002μg/mL
3. Precision: RSD≤0.5%
4. Combustion head: metal titanium
combustion head
5. Atomizer: efficient glass
atomizer
6. Atomizing
chamber: explosion proof corrosion resistant material spray chamber
7. Control
system: automatic PC control six light brick, automatic
alignment, auto optimization and automatic ignition
8. Safety
protection: with automatic safety protection function, anti
temperingautomatic gas path protection, acetylene
gas leakage alarm, automatic shutdown system, abnormal automatic power-off
9. Background
correction: deuterium background correction: correction of the 1A
background
Data processing
1. Measurement
methods: flame method, hydride method
2. Concentration calculation
method: standard curve method (1 ~ 3 times curve),auto
matching, the standard addition
method
3. Repetition
survey frequency: 1-99 times, calculating the average value, standard
deviation and relative standard
deviations are given
4. Results
print: parameters print, data and graphics print, you
can also export WORD, EXCEL document
5. Simple and
convenient operation, lamp position rotating, automatic
ignition through software operating
6. Communication
interface: computer and USB interface communication
ME-AA1800H Features
Flame atomizer
1. Characteristic
concentration (Cu): 0.015 g/mL/1%.
2. Detection
limits of *2.2.2 (Cu): 0.002 g/mL.
3. Precision:
RSD = 0.5%.
4. Combustion head: metal titanium
combustion head.
5. High
performance glass atomizer sprayer.
6. Atomizing
chamber: explosion proof corrosion resistant material spray
chamber.
7. Control
system: the automatic PC control flame / graphite furnace
automatic switch, automatic optimization and
automatic ignition.
8. Safety
protection: with automatic safety protection function, anti
temperingautomatic gas path protection, acetylene
gas leakage alarm, automatic shutdown system, abnormal automatic power-off.
Graphite furnace
atomizer
1. Features (Cd):
0.5 x 10-12g.
2. Detection
limits of (Cd): 0.4 x 10-12g.
3. Precision:
RSD = 3%.
4. Heating method:
vertical heating.
5. Safety
protection: water flow, water temperature, air pressure, the
graphite tubebad contact, flow and power alarm
protection.
6. Conversion mode: flame /
graphite furnace automatic switch machine, electronicmobile platform
software control,
without the need to manually remove.
7. Heating temperature control
mode: room temperature -3000 degrees Celsius,automatic temperature
control up to
20 order, the furnace enriched up to 20 times, 4 kinds of heating mode, longitudinal optically monitoring the graphite tube wall temperature.
Background correction:
1. Flame: deuterium lamp
+ self absorption background correction: correction of the 1A
background.
2. Graphite
furnace: deuterium lamp + self absorption background
correction: correction of the 1A background.
Data processing
1. Measurement
methods: flame method, graphite furnace method, hydride
method.
2. Concentration calculation
method: standard curve method (1 ~ 3 times curve),automatic
matching,
the
standard addition method.
3. Repetition
survey frequency: 1-99 times, calculating the average value, standard
deviation and relative standard
deviations are given.
4. Print print print print
the results of parameters, data, graphics, you can export
Word, Excel document.
5. Simple and
convenient operation, and can be operated through software, to
realize the automatic
conversion of
flame atomizer and a graphite furnace atomizer.
6. Communication
interface: computer and host USB interface communication.
Auto sampler (optional)
1. With 70 sample
cups (2mL), 6 cups for liquid reserves, blank and
matrix modifier, cleaning bottle 500mL, waste
liquid bottle.
2. According to
the need can be arbitrarily specified sample cup and the reagent
cup position, random
arrangement, program
setting, can automatic analysis.
3. Automatic calibration
curve: automatically from a single standard
solution configuration from at least 3 different
concentrations of standard sample, directly into the graphite tube.
4. Needle minimum sample
volume of 1 L 0.1 L incremental selection, selection, sample selection
(maximum 100 L when 10 L-100 selection selection analysis
of L precision is better than 1%).
5. Automatic
long-term memory into the position of the sample needle selection,accuracy
of 50 m.
6. Graphite tube
hole coordinate adjusting range > + 5mm.
7. Automatic depth
adjustment: the sample feeding needle depth changes with
the sample liquid automatic adjustment.
8. Automatic standard
addition method, the standard sample of up to 20.
9. Cleaning
method: internal and external wall while cleaning, cleaning
time and frequency adjustable.
10. Solution
was injected after the automatic start of graphite
furnace heating procedure.
Hydride generator (optional)
1. The
sensitivity of (As): 0.15ng/mL/1%
2. Precision RSD
3%
3. Atomizer: T
type electrothermal quartz absorption tube (corundum jacket, ensure
safety)
4. Automation: only a
start button, press gently to complete sampling, occurrence,determination,
cleaning
of the whole process, can communicate with host on-lineautomatic
reading (host must have this function).
5. Can be applied to
various readings: applicable to a variety of readings, peak
height, peak area of reading reading,
continuous reading.
Detection method and determination
of trace elements:
1. Flame
atomic absorption spectrophotometry:
Flame atomic
absorption spectrophotometry (air acetylene) determination of elements
can be detected PPM level. Sodium (Na), potassium (K), magnesium (Mg), calcium (Ca), chromium (Cr),
manganese(Mn), iron (Fe), cobalt (Co), nickel (Ni), platinum (Pt), gold (Au), copper (Cu), silver (Ag),zinc (Zn),
cadmium (Cd), lead (Pb), bismuth (Bi), etc..
2. Atomic
absorption hydride method:
Atomic absorption hydride
method can be of low melting point elements trace Detection (PPb).
Determination of arsenic, selenium (As): (Se), antimony (Sb), bismuth (Bi), lead(Pb), tin (Sn),
tellurium (Te), germanium (Ge), mercury (Hg) etc..
3. Graphite
furnace atomic absorption spectrometry:
Detection by
graphite furnace atomic absorption, less sample volume, high
sensitivity(PPb).
Silver (Ag), aluminum (Al), arsenic (As), gold (Au), barium (B
|
CV. ANDALAN PRIMA SEJAHTERA JL. Muchtar Tabrani Perum. Bintang Metropol Blok A7No 16 Bekasi Utara 17122 P : 021- 29253336, 29253184, M : 0812-9077-3137 E: maria@andalanprimasejahtera.com