Minggu, 04 Desember 2016

Doule Beam UV/VIS Spectrophotometer ME-UV1800PC/ME-1800APC/ME-1800SPC/ME-1900PC

Product name : Doule Beam UV/VIS Spectrophotometer
Item : ME-UV1800PC/ME-1800APC/ME-1800SPC/ME-1900PC
Details :
 Advantage 
●  Used in biological research, bio-industry, pharmaceutical, pharmaceutical, teaching&research, environmental
    protection, food hygiene, clinical examination , health and epidemic prevention and other fields.
●  4nm, 2nm, 1nm, 0.5nm spectral bandwidth of four customized according to user requirements can be installed
    to meet the stringent requirements of the Pharmacopoeia.
●  LSI design greatly improves the scalability and reliability of the system.
●  Rich measurement methods, with a wavelength scan, time scan, multi-wavelength determination, multi-order
    derivative determination (optional ), dual-wavelength, three-wavelength(optional) DNA protein measurements
    (optional) , and other measurement methods to meet different measurement requirements, and can be displayed
    directly on a 6- inch screen.
●  Based on optional hole rack , manual four with stand , manual Eighth rack , automatic Eighth frame, glass stand,
    test tube rack, 1cm colorimetric frame , 5cm colorimetric frame , 10cm colorimetric racks.
●With USB interface; Can be powered down to save the measurement parameters and data.

 Specifications 
Model
ME-UV1800PC
ME-UV1800APC
ME-UV1800SPC
  ME-UV1900PC
Wavelength Range
190-1100nm
Band Width
1.8nm
1nm
0.5/1,/2/4nm adjustable or 0.5/1/ 4/5nm optional
0.1/0.2/0.5nm;
1.0/2.0/4nm
Wavelength Accuracy
±0.3nm
Wavelength Repeatability
≤0.1nm
Photometric Accuracy
±0.3% T(0-100%T) ±0.002A(0-0.5A) ±0.003A(0.5A-1A)
Photometric Repeatability
0.15% τ0-100%τ) ±0.001A(00.5A) ±0.0015A(0.5A1A)
Stray Light
≤0.03% τ (220nm NaI340nm NaNO2)
Stability
0.0005A/h@500nm
Noise
± 0.0002A @500nm
Baseline Flatness
± 0.001A
Photometric Mode
T,A,C,E
Photometric Range
-44A
Display Mode
6 Inches hight Light blue LCD
Detector
Import Silicon Photodiode
Light Source
Import Deuterium Lamp & Tungsten Halogen Lamp
Power Requirement
120W, AC 220V/50Hz 110V/60Hz
 

Micro-Volume UV/VIS Spectrophotometers UL-2000 & UL-1000

Product name : Micro-Volume UV/VIS Spectrophotometers
Item : UL-2000
Details :
Spectrophotometer is an important analysis instrument wildly applied
in research of physics, chemistry, biology, medicine, material, environment
and modern production management of chemistry, medicine, environment
test, metallurgy. Spectrophotometer is the instrument for quantitative and
qualitative research by spectrophotometry. It is usually used in quantitative
research of nucleic acid,proteins and bacterial concentration.

 Feature 
l Micro scale sample test, minimum 0.5u1, ultromicro and cuvette are possible
l Wildly test area, 100 times of the traditional spectrophotometer
l No need to dilute for most samples
l Test directly, no need to warm-up, container test and daily consumption test
l Whole wavelength 190-1100nm, accuracy 1nm, auto scanning wavelength 190-850nm
l Compact size and portable package fit-able for on-site test
l More accurate and flexible test is realized by PC control

 Specification
Model
UL-2000
Minimum sample capacity
0.5ul
Ultromicro optical distance
1mm/0.2mm/0.05mm (available)
Cuvette optical distance
10mm/5mm/2mm/1mm
Wavelength band
190-850nm
Wavelength accuracy
1nm
Wavelength resolution
≤0.3nm(FWHM at Hg 253.7nm)
Test accuracy
0.01~0.5 Abs.±0.01Abs 0.5~80 Abs.±2%
Sample test platform material
304 stainless steel and quartz
Absorbance accuracy
2%(0.76 at 257nm)
Absorbance resolution
0.002Abs(1mm)
Absorbance area
0.005~80 (10mm)
Detector
3648 pixel linear CCD array
Light source
Import Xenon Lamp
Text time
8s
Size
200mm* 130mm * 136mm(L*W*H)
Weight
≤ 2.5kg
Voltage
AC100~240V 50~60Hz
Power
24W

 Standard Accessories 
● photometer 1 pc              ●Power line 1 pc
● Power Adapter 1 pc         ●Factory inspection report
● Driver software CD          ●Instruction manual 1 pc

Product name : Micro-Volume UV/VIS Spectrophotometer
Item : UL-1000
Details :
     Spectrophotometer is an important analysis instrument wildly applied
in research of physics, chemistry, biology, medicine, material, environment
and modern production management of chemistry, medicine, environment
test, metallurgy. Spectrophotometer is the instrument for quantitative and
qualitative research by spectrophotometry. It is usually used in quantitative
research of nucleic acid,proteins and bacterial concentration.

 Feature 
l Micro scale sample test, minimum 0.5u1
l Wildly test area, 100 times of the traditional spectrophotometer
l No need to dilute for most samples
l Test directly, no need to warm-up, container test and daily consumption test
l Whole wavelength 190-1100nm, accuracy 1nm, auto scanning wavelength 190-850nm
l Compact size and portable package fit-able for on-site test
l More accurate and flexible test is realized by PC control

 Specification
Model
UL-1000
Minimum sample capacity
0.5UL
Optical distance
1 mm/0.2mm
Wavelength band
190一850nm
Wavelength accuracy
l nm
Wavelength resolution
≤0.3nm(FWHM at Hg 253.7nm)
Absorbance accuracy
2%(0.76 at 257nm)
Absorbance resolution
0.002Abs(1mm)
Absorbance area
0.02~80(10mm)
Test accuracy
0.1~5 Abs. ±0.1 Abs   5~80 Abs. ±2%
Sample test platform material
304 stainless steel and quartz
Detector
3648 pixel linear CCD array
Light source
mini HID
Text time
8s
Size
200mm *130mm * 136mm(L*W*H)
Weight
≤2.0kg
Voltage
AC100~240V 50~60Hz
Power
24W

 Standard Accessories 
● photometer 1 pc              ●Power line 1 pc         
● Power Adapter 1 pc        ●Factory inspection report
● Driver software CD         ●Instruction manual 1 pc

M E-F96PRO Fluorescence spectrophotometer

Fluorescence spectrophotometer

Product name : Fluorescence spectroph
otometer
Item : ME-F96PRO
Details :
 Applications 
This method can provide information including excitation and emission spectrum, emission
light intensity and measurement of life of emission light and polarization fluorescence etc.
This method can provide a wide lineal range of working curve.
It has becoming an important analytic method in the region of trace analysis.
This method has been used in:Medical science and clinical analysis:Clinical analysis of biological specimen.Pharmaceutical science and pharmacology:Analysis of natural pharmaceutical products; Quality control of pharmaceuticals and
                                                                              research of 
 pharmaceutical metabolites.Biochemistry: Analysis of minute quantity of substances in biological body.Food industry:Analysis of minute quantity of constituents in food.Pollution analysis:Atmospheric pollution,environmental testing&food contamination analysis.

Organic and inorganic chemistry:
Used in the trace analysis in case of those substances cannot be determined by absorption
                                                            spectrophotometry.

 Features 

1.       Two operation mode could be chosen: fluorescence intensity and luminous intensity. Fluorescence scanning, kinetic
determination and quantity analysis could be done under fluorescence intensity mode.
2.      Support off-line mode and on-line mode. Under off-line mode, instrument's computer system offer the fluorescence intensity
measurement, concentration direct reading, auto 0 adjustment, auto background subtraction and etc. Under on-line mode,
we could use quality and quantity software to control data acquisition and analysis through USB2.0 interface.
3.     Provide optional PC qualitative and quantitative software package with expansible time scanning, wavelength scanning,
graphic calculation and storage-access abilities.
4.     Optional accessories for different measurement, including single hole cell holder, fluorescence sample holder for different
features, 200μl micro scale centrifuge tube, micro scale capillary sample holder, semi-auto sample introduction accessories,
membrane sample accessories, powder sample accessories, jacket sample accessories and etc.

 Specifications 

Model
ME-F96PRO
Exciting optical filters
Interference optical filter (10nm bandwidth)
Wavelength
365nm
Emission monochromator
C-T diffraction grating(Em 200-900nm)
Wavelength accuracy
±1nm
Wavelength repeatability
≤0.5nm
Sensitivity
S/N150
Linearity deviation
≥0.995
Stability
better than 1.5%/10min
Display value
0.00-600.00
Power
220V±22V  50Hz±1Hz
Interface
USB2.0
Size
550*510*365(mm)&13kg